Shopping Cart: MyProfile | Log Out
0   Items  In Cart |  Total: $0.00

Abbeon
AEMC
Alnor
Amprobe
APG
Atago
Bacharach
Checkline
Compact Inst.
Cooke
Datatrack
Defelsko
Dickson
Digimed
Extech
Fluke
F.W. Bell
GIC
Global Water
Goldak
Graphtec
Hanna
Honeywell
Instek
Jenco
McDonnellMiller
Megger
Monarch
Novasina
Oakton
Partlow
Reed
Revere
Rotronic
Rustrak
Shimpo
Signet
Vulcain
West Instruments
YSI
See Whole List . . .

Clamp-On Meters
Electrical
Force Meters
Multimeters
Power Quality Analyzers
Stroboscope
Tachometers
See Whole List . . .

Air Quality
Combustion Gas Analyzer
Controllers
LightMeters
SoundMeters
See Whole List . . .
Flow
Level
Pressure
Data Chart
Panel Indicator
Paperless
Humidity
Thermometers
Water Quality




Temperature Calibration Instruments
Back to Ametek

Ametek Temperature Products
Dry Block Calibrators | Reference Probes | HandHeld Thermometers | Temperature Calibrators
HandHeld Pressure Calibrators | Pressure Testers | Deadweight Testers | Signal Calibrators
Software



Jofra Dry-Block Calibrators
ATC Series | ITC Series | CTC Series | ETC Series
Dry-block calibrators for fast and efficient true temperature calibration. Designed for both on-site and laboratory use. Temperature range: -45° to 1200°C @ 23°C / -49° to 2200°F @ 73°F

JOFRA ATC SERIES DRY-BLOCK CALIBRATORS
A complete precision on-site test laboratory
The JOFRA ATC series combines the accuracy of a laboratory calibrator with the speed and portability of a dry-block calibrator. The series features the new dual-zone heating/cooling block to ensure the thermal performance in the calibration zone independent of the load.
All units with dual-zone heating block
New super-cooling model (ATC-157)
Universal input for sensor-under-test
Input for external reference probe
Automatic switch test
RS 232 and AmeCal calibration software
Multi information display + numeric keyboard
Autostepping
Stability indicator
Count-down timer (shows when unit is stable)
Automatic, stand-alone calibration system
Up- and download of work orders (calibrations)
MVI Mains Variance Immunity

Model Temperature Range
ATC-156 -24 to 155°C (-11 to 311°F)
ATC-157 -45 to 155°C (-49 to 311°F)
ATC-320 33 to 320°C (122 to 1202°F)
ATC-650 33 to 650°C (122 to 1202°F)

Click Here For A Quote
JOFRA ITC SERIES DRY-BLOCK CALIBRATORS
Accurate and easy-to-use true temperature calibration in the field
The JOFRA ITC series of dry-block calibrators has been designed for accurate true temperature calibration in the field. The ITC series features a modified dual-zone heating block from the ATC series. This means much better calibration uncertainties throughout a broad varieties of temperature sensors. The simple operation and the automatic functions have been carefully selected for ease of use. The ITC series is an efficient temperature calibrator without compromising quality.
Dual-zone heating block
Interchangeable inserts
Multi-hole insertion tubes
MVI Mains Variance Immunity
Automatic switch test
RS 232 and calibration software
Multi information display
Safety banana bushings
Auto stepping
Stability indicator
Count down timer (shows when unit is stable)
Programmable maximum temperature
Fast simulation/training mode
Re-calibration from keyboard

Model Temperature Range
ITC-155 A -23 to 155°C (-9 to 311°F)
ITC-320 A 50 to 320°C (122 to 608°F)
ITC-650 A 50 to 650°C (122 to 1202°F)

Click Here For A Quote
JOFRA CTC SERIES DRY-BLOCK CALIBRATORS
Fast and easy-to-use reliable true temperature calibration in the field
The JOFRA CTC series of dry-block calibrators has been designed for much easier true temperature calibration in the field, leading to reliable results. The simple operation and the automatic functions have been carefully selected for ease of use. This has resulted in a fast, simple and efficient temperature calibrator without compromising quality. Reach 320°C / 608°F in just 4 minutes
Interchangeable inserts
Multi-hole insertion tubes
MVI Mains Variance Immunity
Automatic switch test
RS 232 and calibration software
Multi information display
Safty banana bushings
Auto stepping
Stability indicator
Count down timer (shows when unit is stable)
Programmable maximum temperature
Fast simulation/training mode
Re-calibration from keyboard

Model Temperature Range
CTC-140 A -17 to 140°C / -1 to 284°F
CTC-320 A 33 to 320°C / 91 to 608°F
CTC-320 B 33 to 320°C / 91 to 608°F
CTC-650 A 33 to 650°C / 91 to 1202°F
CTC-650 B 33 to 650°C / 91 to 1202°F
CTC-1200 A 300 to 1200°C / 572 to 2200°F

Click Here For A Quote
JOFRA ETC SERIES DRY-BLOCK CALIBRATORS
Probably the fastest dry-block calibrator in the world
The JOFRA ETC 400A heats up by up to 100°C / 212°F per minute and completes a full dual-point test in less than 10 minutes, including stability time; timesavings at your fingertips!
The JOFRA ETC series is designed for field testing of temperature measurement devices. The small size and light weight make it a perfect instrument to verify sensors in difficult to reach places.
The JOFRA ETC 400R is designed for fast and reliable calibration of infrared thermometers.
All JOFRA ETC units have many of the same useful and timesaving features as the more advanced JOFRA dry-block series.
Complete series of temperature and IR calibrators
Multi-hole well design
RS 232 and calibration software
Multi information display
Auto stepping
Stability indicator
Count down timer (shows when unit is stable)
Programable maximum temperature
Fast simulation/training mode
Re-calibration from keyboard

Model Temperature Range
ETC125A -10 to 125°C / 14 to 257°F
ETC400A 28 to 400°C / 28 to 752°F
ETC400R 28 to 400°C / 28 to 752°F

Click Here For A Quote
JOFRA STS-100 SERIES REFERENCE PROBES
Fast response time, low immersion depth, small physical sizes, and low drift rate
The STS-100 A series of industrial reference probes is based on many years of experince in temperature measurement and calibration. This series features fast response times, low immersion depth, small physical size, and a specified low drift rate, even at high temperatures.
Wide temperature range -150 to 650°C (-238 to 1202°F)
High system accuracy 0.03°C (0.054°F) including the DTI-1000)
Long-term burn-in procedure up to 650°C (1200°F)
Perfect for dry-block calibrators
Special 90° angled probe for use in dry-blocks. Room for sensor under test
Accredited certificate up to 650°C (1202°F) as standard delivery

Click Here For A Quote
AMETEK ETM SERIES HANDHELD THERMOMETERS
Complete systems - build for your application
The ETM-2000 series consists of 5 different systems and covers a broad variety of temperature applications. The series has 3 systems for thermocouples and 2 for Pt100 sensors. Both Pt100 models have IP67 (water proof) density, which make them well-suited for use in dairy wet rooms, slaughterhouses, and similar food environments. 3 of the 5 systems have a 'SpeedRead' function, which calculates the temperature after just 14 seconds in the medium, a great timesaving feature when measuring granulates, powders, and atmospheres. Data logging is an option in the Pt100 system as well as in the thermo element system. Results are shown on the display or on a PC.
Complete solutions (minimize the risk of errors)
Flexible solutions (may be supplemented as needs change)
The instrument is 'industry protected' (IP65 and IP67) with a rubber boot
Systems dedicated for the food industry, HVAC, or general industry
Systems available with or without data logging and software for documentation of critical measurements


Temperature Calibrators
Click Here For A Quote
JOFRA DTI-1000 REFERENCE THERMOMETER
A rugged handheld battery operated thermometer for lab and field use
The JOFRA DTI-1000 is a battery-operated portable reference thermometer. Use the DTI-1000 wherever you have a demand for reliable and accurate temperature measurements. The rugged design and the battery operation make it ideal for use in laboratories or in the field. The DTI-1000 has proven its performance and reliability through years of trouble-free operation in many national laboratories all over the world.
High accuracy 0.014°C (0.025°F)
Resolution 0.1 - 0.01 or 0.001
True-Ohm measuring principle
Dual channel inputs A and B, with differential value A-B, peak hold, etc.
Range -200°C to 750°C (-328°F to 1,382°F)
Battery or mains adapter supply
Integrated in the calibration software 'AmeCal Temperature'
RS-232 interfase as standard
Scalable Analog output
Calibration and datalogging PC software included (DOS)


HandHeld Pressure Calibrators
New enhanced product in place; see JOFRA CPC series and JOFRA APC series
Click Here For A Quote
JOFRA PPC & PPCE PRESSURE CALIBRATION SYSTEMS - OBSOLETE
Precision pressure calibrators for easy, traceable, field calibration of pressure gauges
PPC and PPCE series are portable, self-contained precision instruments designed for critical process applications where accuracy, flexibility, and quality cannot be compromised.
Click Here For A Quote
AMETEK CalPal PRESSURE CALIBRATOR- OBSOLETE
Economical general purpose electronic calibrator
The AMETEK CalPal is a popular and easy to use digital pressure calibrator. The unit is available as an indicator or as a complete system. All systems are delivered complete with an AMETEK hand held pump and a carrying case. The pressure ranges are 0.7, 2 or 14 bar (10, 30 or 200 psi). Accuracy including linearity, hysteresis and repeatability is better than ±0.1% of full scale.


Pressure Testers
Pneumatic Pump Systems | Hydraulic Pump Systems

Pneumatic Pump Systems
All pump systems may be purchased separately or as a part of one of the many AMETEK pressure calibration systems.
T-810 and T-811
T-810 designed for applications up to 15 bar (200 psi). T-811 designed for vacuum applications down to 635 mmHg (25 inHg). Both pumps are supplied with NPT or metric fittings.
VP hand pump
Scissor hand pump for pressure from vacuum to 15 bar (200 psi). Dual pressure output, fine adjustment and release valve. Max. pressure setting
T-730 and T-740 and T-750 hand pump
T-730 for pressure up to 2 bar (30 psi).
T-740 for pressure up to 15 bar (200 psi)
T-750 for use in vacuum applications down to 635 mmHg (25 inHg). Pumps feature dual pressure output, fine adjustment, and release valve.
May be supplied without hoses.
Click Here For A Quote
HYDRAULIC PUMP SYSTEMS
All pump systems may be purchased separately or as a part of one of the many AMETEK pressure calibration systems.
T-620 hand pump
T-620 For high pressure applications up to 200 bar (3,000 psi).
T-620H for pressure up to 350 bar (5,000 psi).
Pressure media is oil. Dual pressure output, fine adjustment, release valve and oil reservoir.
65-PO16 screw pump
Screw pump up to 350 bar (5,000 psi). For oil or water (SKYDROL®' available), quad pressure output manifold (fine adjustment and liquid reservoir optional).
65-P014 hydraulic pump
Pressure media is oil. Up to 700 bar (10,000 psi). Triple pressure output manifold, fine adjustment and liquid reservoir.
Type T and type R hydraulic pump
Pressure media is water or oil for the type T pump and max. pressure is 1,000 bar (15,000 psi). The type R pump is for oil and max. pressure is 700 bar (10,000 psi). Both pumps have dual pressure output manifold, fine adjustment, release valve and the dual volume control valve. These pumps are standard with Buna o-rings however they are available with Viton or EPT o-rings as an option.


Deadweight Testers
Pneumatic Tester | Hydraulic Tester | Accessories

PNEUMATIC DEADWEIGHT TESTERS
Recognized for their ease-of-use, reliability, and overall performance
These self-regulating floating-ball testers offer a high level of accuracy independent of the operator and have earned their reputation as the 'standard of primary standards'. AMETEK pneumatic deadweight testers are available for pressures as low as 4 inH2O (10 cmH2O) or as high as 1500 psi (100 bar). AMETEK pneumatic testers have accuracies up to ±0.015% of reading and repeatability up to ±0.005% of reading. These testers are superior to all digital systems.
Applications
The ideal primary standard
Calibrate instruments used in critical process control loops and extend the time between calibrations due to better accuracy and uncertainty
Calibrate instruments on custody transfer stations and reduce the uncertainty of the measurement
Reduce maintenance costs by calibrating your portable digital calibrators and achieve the highest possible accuracy
Ideal for hazardous locations
Click Here For A Quote
MODEL RK
Accurate up to ±0.015%
of indicated reading, this primary standard is ideal for pressure ranges from 1 to 300 psi (0.01 to 20 bar) and provides for incremental pressures down to only 0.1 psi (1 mbar). Available in seven different engineering units: inH2O, psi, kPa, cmH2O, inHg, bar and kg/cm2. Features a cast metal base with quick levelling for field or laboratory use. Also operates with cover closed.
MODEL PK ll
Low pressure tester, portable and ideal for field or laboratory use. The PK II tester is used for low pressure applications up to 30 psi (2 bar). Available in 7 engineering units: psi, g/cm2, kPa, bar, inH2O, cmH2O, and mmHg. This industry standard has an accuracy of up to ±0.015% of reading. Housed in a rugged case made for 'closed case' operation to protect from wind conditions. The tester base includes a built-in mounting for optional tripod use. Also available for medical applications ready for use with Oxygen.
MODEL HK
High pressure tester for high pressure applications up to 1,500 psi (100 bar), AMETEK HK series testers operate in the same easy manner as the Model PK II and RK testers. HK testers feature an accuracy up to ±0.025% and a repeatability of up to ±0.005% of reading. Available in psi, kg/cm2, kPa and bar engineering units.


Hydraulic DEADWEIGHT TESTERS
Achieve the highest possible accuracy of pressure generation and measurement
Superior to digital systems, AMETEK testers offer excellent performance and long term stability and they feature a proven design that will deliver years of trouble-free operation.
Applications
Repeatability better than ±0.005% of reading
Accuracy up to ±0.025% of reading and even better using a DADT converter
Dual volume control valve delivers high volume to rapidly build pressure
Vernier adjustment for fine adjustment of pump pressure
Re-entrant type piston and cylinder assembly maintains accuracy as test pressure increases and improves the spin and float times
Single and dual-column versions. Conversion kits available
Enclosed piston/cylinder assembly for safe operation
Available engineering units: psi, bar, kPa, kg/cm2
Click Here For A Quote
DEADWEIGHT TESTER TYPE T
These high accuracy deadweight testers are ideal for laboratory or field use. The type T tester uses distilled water or fluid compatible with 300 series stainless steel and MONEL (including AAA tester oil). For applications up to 15,000 psi (1,000 bar). An optional dual piston lets you interchange piston/cylinder assemblies to extend the pressure measurement range using the same weight set. A kit is available for converting to a dual column tester.
DUAL COLUMN
Separate columns are provided for high and low pressure measuring piston/ cylinder assemblies. Range changes are achieved using a built-in crossover valve that allows three-point calibrations to be performed in seconds. It is not necessary to purchase a second set of weights. Fill fluids and pressure ranges are the same as type T single column testers.
HYDRALITE (HL) PORTABLE DEADWEIGHT TESTER
This extremely compact, self-contained portable tester is designed for pressure ranges from 10-200 psi (1-15 bar) up to 50-3,000 psi (5-225 bar). Accurate to ±0.05% of reading, the unit features an easy-to-use screw pump with ratcheting handle and re-entrant type piston/cylinder assembly. This helps maintain accuracy as the test pressure increases. Weights and piston assemblies are interchangeable. The unit's AAA tester oil may be easily inspected through the transparent reservoir. Compact design in only 9 x 9 x 10 in (23 x 23 x 24.5 cm). Tripod option available for field applications.
Click Here For A Quote
DADT DIGITAL ACCESSORIES
Improve the performance of your deadweight tester
This pre-programmed, intrinsically safe accessory corrects for ambient conditions and inherent errors associated with any hydraulic or pneumatic deadweight tester application. It uses actual values rather than nominal values to correct for the specific gravity of location, masses of the weights, weight set buoyancy in the air, relative humidity, and temperature effects. Eliminates most errors by calculating the NIST formula provided by Test III data. Features fifteen engineering units with automatic conversion. Lets you use a psi tester for H2O calibrations.


Signal Calibrators

ModCal II
The Complete Instrument Shop in a Box ™
Complete system for calibrating and dataloffing all process instruments: Temperature, Pressure, Frequency and other measurements.
Flexible modular system allows user selection of calibration features.
Accuracy of ±0.5% of reading traceable to NIST or international standards. Includes linearity, hysteresis and repeatability.
Stores customized calibration programs for over 200 types of instruments.
RS-232C Serieal port for interface with PC, printer, or other compatible equipment.
Lightweight, Compact, Rugged and Weather Resistant.
Click Here For A Quote
JOFRA MULTI LOOP SIGNAL CALIBRATOR -- OBSOLETE --
New enhanced product in place; see JOFRA ASC300
The JOFRA MLC multi loop calibrator offers a wide choice of measuring, simulation and calibration combinations including autostepping, ramping, transmitter calibration, scaling, selectable standards, cold junction compensation, loop testing and more.


TEMPERATURE CALIBRATION SOFTWARE

AMECAL-TEMPERATURE & AMECAL-LIGHT
An easy way to run and document your temperature calibrations
Simplify and improve the efficiency of your temperature calibrations using AMECAL-TEMPERATURE or AMECAL-LIGHT software. This WINDOWS®-based software makes use of standard WINDOWS tools including menu bars and icons and can be used with all JOFRA dry-block calibrators.
AMECAL-TEMPERATURE software provides you with an easy method for calibrating, write out calibration certificates, data logging, and managing your calibration data.
AMECAL-LIGHT software have all the same features but can not store your results.
The key to an easy setup of a calibration task is the unique "Icon bar". The "Icon bar" tells you where you currently are in the calibration process, starting with selection of the sensor to be calibrated and ending by performing the calibration. The AMECAL software will improve the accuracy of your calibrations. Select the right calibration "scenario" and the software will communicate with both the heating source and the JOFRA DTI-1000 reference thermometer at the same time. All "true temperature readings" will be taken from the more accurate JOFRA DTI-1000 thermometer!
Click Here For A Quote

Visit the OMNI Controls Home Page Contact Us